Back to Hilborn Home Page

Technical Support - Mechanical - Fuel Injector Manifolds
Return to Technical Support

How to set the metering valve

Set injector to wide open throttle. As pictured in the Metering Valve Schematic, the distance “X” between the center of the rod-end bearings is equal to the disctance “Y” between the center of the throttle shaft and the center of the metering valve rotor (#54 shown). Note that the inlet fitting on the block is off-set to one side. Adjust the rotor so that the number is located on the wide side of the off-set. Tighten arm on the rotor and the throttle shaft.

 

Downloads

Metering Valve Schematic

 

 

All Content ©2000, HILBORN Fuel Injectors, All Rights Reserved | Sales Policy | Site design by portallogic